Flux Regeneration System
The fluxing bath is being polluted by acid residues and above all by dissolved iron.
Consequently it makes the quality of the galvanizing process worse; moreover iron
being entrained by a polluted fluxing flow into the galvanizing bath binds itself with
zinc and precipitates to the bottom, thus increasing dross. A continuous treatment of
the fluxing bath will help you get rid of this problem and cut the zinc consumption
dramatically.
From the flux tank a certain quantity of liquid is pumped to the reaction tank. In the
reaction tank the liquid reacts with various chemicals through automated system of
dosing. From the reaction tank the liquid is pumped to the filter press which separates
the iron from the liquid. The clean liquid is pumped back to the flux tank.
- Continuous automatically operated Flux Cleaning & regeneration system with capacity up to 8000 LPH.
- Comprised of Digital display controller for iron content and pH reading.
- Features allow the setting of the pH & iron content level as per client’s requirement.
- Results in reduced zinc pick up and lower dross production.
- Includes safety switches to have controlled operation.